Generator Lima/Marathon MagnaPLUS 94KW with Single Phase/Three Phase Switch. Provides full 500A@120V output in Single Phase and in Three Phase. Marine rated rectifier with surge suppression. CSA listed. Frequency Control Woodward digital electronic controller with integrated actuator. No external linkage to maintain. Crystal accuracy for HMI lighting. Size/Weight With Trailer: Length: 154", Width: 86", Height: 72" Without Trailer: Length: 96", Width: 36", Height: 50" Weight: Trailer, generator, and fuel: 3500 lbs. (1590 kg) Weight: Generator and fuel: 3000 lbs. (1363 kg) Noise Level Less than 50 db(A) @ 50 feet. Controller Engine control, AC monitoring, fault and pre-fault systems are provided by a microprocessor-based system. All readouts are digital and are listed below. Weather-proof glass cover. Monitoring | Faults and Pre-Faults | AC Voltage - All Legs | Oil Pressure Fault/Pre-Fault | Amperage - All Legs | Water Temp Fault/Pre-Fault | Frequency - All Legs | Over Crank Fault | Oil Pressure | Over Speed Fault | Water Temperature | Low Fuel Fault and Pre-Fault | Battery Voltage | Low Battery Pre-Fault | Fuel Level | Defective Oil Sending Unit Pre-Fault | Time To Next Service | Defective Water Sending Unit Pre-Fault |
Fuel Tank 60 Gallon tank is standard. | Load | Gallons/Hour | | 500A | 14:45 | | 375A | 18:45 | | 250A | 25:20 | | 125A | 42:00 |
|